The AMIS60 is a 4 channel, 60 watt mixer amplifier suitable for rack or desk
mounting. The amplifier is a self contained compact unit of solid steel
construction. The amplifier may operate from mains power or 24V DC.
Inputs
The AMIS60 has four universal input channels with separate level controls.
Each channel will accept balanced or unbalanced microphone, line and auxiliary
inputs. The unit has industry standard XLR microphone sockets and dual RCA
auxiliary sockets for each channel. Line input 4 has a lower input sensitivity
and is suitable for high level CD players. An insert point is also featured on
the rear panel for those applications where an additional EQ or feedback
exterminator may be required.
Outputs
The AMIS60 features 100 volt, 70
volt and 8 ohm isolated transformer outputs, plus a tape recorder output by
means of dual RCA sockets. A balanced 700mV XLR output is also provided to feed
up to 6 power amplifiers. A vox triggered relay output is also available on the
rear panel for activation of external devices from the vox muting circuit. In
most cases this would be used as a muting bypass relay, which when used with the
appropriate external attenuator will maintain preset paging levels irrespective
of the attenuator setting.
Speaker Zone Selector
A six position push
button speaker zone selector with overriding "all call" is located on the front
panel. Each of the six zone selectors switch the 100 volt speaker line output to
6 separate speaker zones. The "all call" selector overrides all 6 zones
regardless of their on/off condition and places the 100 volt output to all 6
zones.
Tone Generator
The AMIS60 comes standard with an in-built four
tone generator module. Tones include Bell, Pre-announce Chime, Alert Tone
(AS2220.1) and Evacuate Tone (AS2220.1). Any of these tones may be activated
from a simple contact closure connected to the rear panel of the amplifier. A
Pre-announce defeat switch is located on the front panel.
VCA Control
The master volume can be controlled remotely. External VCA control would
normally be via a 500K pot connected to a two wire rear panel barrier strip.
Muting
VOX muting is standard on the AMIS60. A mic or line signal on
channels 1 or 2 will mute channels 3 and 4. The muting function can be disabled
via an internal link.
Phantom Power
Phantom Power (18V DC) is available
from all mic inputs. A rear panel phantom power on/off switch is also provided.
Protection
Internal current limiting protects the amplifier from both
overload and overdrive conditions. Australian Monitor Installation Series
amplifiers feature a protection network that provides greater stability and
performance. Our amplifiers are recognised worldwide for their reliability and
this is due to the extensive levels of current limiting which protect the
amplifiers from both overload and overdrive conditions.